1. SAFETY INSTRUCTIONS 4
1.1. Power Supply 5
1.2. Power Cord and Other Cables 5
1.3. Humidity and Water 5
1.4. Cleaning 6
1.5. General Precautions 6
2. OPERATING INSTRUCTIONS 12
2.1. Product Description 12
2.2. Product Usage 12
2.3. Maintenance 53
2.4. Troubleshooting 55
2.5. Technical Specifications 56
3. POSTSALE SERVICE 57
4. ENVIRONMENTAL PROTECTION 57
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 3 21/01/2019 10:24
4
1. SAFETY INSTRUCTIONS
Important Warnings
Before using your appliance read these instructions manual carefully
and keep it in a safe place as you may need to consult it in the future.
Before turning on your appliance, and to ensure a safe and correct
operation, do not use if:
• It has fallen to the ground;
• You notice any evidence of damage;
• Any anomaly occurs during its operation.
To avoid hazards or deterioration of your appliance through incorrect
use it is advisable to read these instructions thoroughly.
Your appliance may not be used for other purposes than the ones
intended and solely for household use. Any damage resulting from
using the appliance outside this scope, any incorrect use, as well as
any manual modifications to the product will not be covered and
automatically voids the warranty.
WARNING
RISK OF ELECTRIC SHOCK
DO NOT OPEN
Warning: to avoid the risk of electric shock, do not
remove the cover. The interior does not contain any parts
that can be repaired by the user. Ask for the Customer
Support Service.
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 4 21/01/2019 10:24
5
EN
Portable air conditioner | Aire acondicionado portátil | Ar Condicionado Portátil
Assistance
In case of malfunction, take your appliance to the Customer Support
Service for assistance.
This appliance can be used by children from the age of 8 and by
people with reduced physical, sensorial or mental capabilities and/or
lack of experience and knowledge if they have been given instructions
on using the appliance safely and if they understand the hazards
involved. Children may not play with the appliance. Cleaning and
maintenance must not be carried out by children without supervision.
These instructions are also available at www.suporteworten.pt
1.1. Power Supply
Make sure the main voltage is compatible with the appliance’s. If this is
not the case, please consult the Customer Support Service.
1.2. Power Cord and Other Cables
Do not tangle the cord or pull it to disconnect the appliance. Also, keep
the cord away from warm surfaces.
Never use the appliance if it has a damaged cable or socket.
Take it to the Customer Support Service for replacement.
1.3. Humidity and Water
Do not use your appliance in humid places. Do not allow the appliance
to become wet under any circumstances as this may be dangerous.
To avoid re hazard or electric shock do not expose your appliance
to humidity or water. Furthermore, do not place your appliance under
water (e.g. for cleaning).
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 5 21/01/2019 10:24
6
1.4. Cleaning
Before cleaning, be sure to switch o the appliance and remove the
plug from the main power supply. Always allow the unit to cool down
before cleaning.
To clean the exterior of the product, use a dry soft cloth only.
1.5. General Precautions
Please follow the instructions in the user manual which will help you
to properly install and operate this product and enjoy its advanced
features. Please keep the instructions for future reference.
Read all instructions before using the product.
Maintenance and service operations are only to be carried out by
authorized professionals.
Any damage caused by manual modications to the product is not
covered by the warranty.
If this product is used for other purposes than the ones originally
intended, or if it is not correctly connected, the product may become
damaged and the warranty will be voided.
This symbol indicates that ignoring instructions may cause
death or serious injury.
Warning: To prevent death or injury to the user or other people
and property damage, the following instructions must be followed.
Incorrect operation due to ignoring of instructions may cause death,
harm or damage.
Installation must be performed according to the installation
instructions. Improper installation can cause water leakage, electrical
shock, or re.
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 6 21/01/2019 10:24
7
EN
Portable air conditioner | Aire acondicionado portátil | Ar Condicionado Portátil
Use only the included accessories and parts, and specied tools for
the installation. Using non-standard parts can cause water leakage,
electrical shock, re and injury or property damage.
Make sure that the outlet you are using is grounded and has the
appropriate voltage. The power cord is equipped with a three-prong
grounding plug to protect against shock. Voltage information can be
found on the nameplate of the unit.
Your unit must be used in a properly grounded wall receptacle. If
the wall receptacle you intend to use is not adequately grounded or
protected by a time delay fuse or circuit breaker (the fuse or circuit
breaker needed is determined by the maximum current of the unit.
The maximum current is indicated on the nameplate located on
unit), have a qualied electrician install the proper receptacle.
Install the unit on a at, sturdy surface. Failure to do so could result
in damage or excessive noise and vibration.
The unit must be kept free from obstruction to ensure proper
function and to mitigate safety hazards.
DO NOT modify the length of the power cord or use an extension
cord to power the unit.
DO NOT share a single outlet with other electrical appliances.
Improper power supply can cause re or electrical shock.
DO NOT install your air conditioner in a wet room such as a
bathroom or laundry room. Too much exposure to water can cause
electrical components to short circuit.
DO NOT install the unit in a location that may be exposed to
combustible gas, as this could cause re.
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 7 21/01/2019 10:24
8
The unit has wheels to facilitate moving. Make sure not to use the
wheels on thick carpet or to roll over objects, as these could cause
tipping.
The appliance with electric heater shall have at least 1 meter space
to the combustible materials.
Do not touch the unit with wet or damp hands or when barefoot.
If the air conditioner is knocked over during use, turn o the unit
and unplug it from the main power supply immediately. Visually
inspect the unit to ensure there is no damage. If you suspect the
unit has been damaged, contact a technician or the Customer
Support Service for assistance.
During a thunderstorm, the power must be cut o to avoid damage
to the machine due to lightning.
Your air conditioner should be used in such a way that it is
protected from moisture. e.g. condensation, splashed water, etc. Do
not place or store your air conditioner where it can fall or be pulled
into water or any other liquid. Unplug immediately if it occurs.
All wiring must be performed strictly in accordance with the wiring
diagram located inside of the unit.
The units circuit board (PCB) is designed with a fuse to provide
overcurrent protection. The specications of the fuse are printed on
the circuit board, such as: T 3.15A/250V, etc.
Cautions
Do not remove any xed covers. Never use this appliance if it is not
working properly, or if it has been dropped or damaged.
Do not run the cord under carpeting. Do not the cover cord with
throw rugs, runners, or similar coverings. Do not route the cord
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 8 21/01/2019 10:24
9
EN
Portable air conditioner | Aire acondicionado portátil | Ar Condicionado Portátil
under furniture or appliances. Arrange the cord away from traic
area and where it will not be tripped over.
To reduce the risk of re or electric shock, do not use this fan with
any solid-state speed control device.
The appliance shall be installed in accordance with national wiring
regulations.
Do not cover or obstruct the inlet or outlet grilles.
Do not use this product for functions other than those described in
this instruction manual.
Disconnect the power if strange sounds, smell, or smoke comes from it.
Do not press the buttons on the control panel with anything other
than your ngers.
Do not operate or stop the unit by inserting or pulling out the power
cord plug.
Do not use hazardous chemicals to clean or come into contact
with the unit. Do not use the unit in the presence of inammable
substances or vapour such as alcohol, insecticides, petrol, etc.
Always transport your air conditioner in a vertical position and stand
it on a stable, level surface during use.
Hold the plug by the head of the power plug when taking it out.
Turn o the product when not in use.
Warnings
Do not use means to accelerate the defrosting process or to clean
other than those recommended by the manufacturer.
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 9 21/01/2019 10:24
10
The appliance shall be stored in a room without continuously
operating ignition sources (for example: open ames, an operating
gas appliance or an operating electric heater)
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Appliance BAC4255 12BTUS should be installed, operated and
stored in a room with a oor area larger than 11 m2.
Compliance with national gas regulations shall be observed.
Keep ventilation openings clear of obstruction.
The appliance shall be stored so as to prevent mechanical damage
from occurring.
A warning that the appliance shall be stored in a well-ventilated area
where the room size corresponds to the room area as specied for
operation.
Any person involved with working on or breaking into a refrigerant
circuit should hold a current valid certicate from an industry-
accredited assessment authority, which authorises their competence
to handle refrigerants safely in accordance with an industry
recognised assessment specication.
Servicing shall only be performed as recommended by the
equipment manufacturer. Maintenance and repair requiring the
assistance of other skilled personnel shall be carried out under
the supervision of the person competent in the use of ammable
refrigerants.
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 10 21/01/2019 10:24
11
EN
Portable air conditioner | Aire acondicionado portátil | Ar Condicionado Portátil
Important note: Read this manual
carefully before installing or
operating your new air conditioner
unit. Make sure to save this manual
for future reference
Explanation of symbols displayed on the unit
WARNING This symbol shows that this unit uses a
flammable refrigerant. If the refrigerant is
leaked and exposed to an external ignition
source, there is a risk of fire.
CAUTION This symbol shows that a service personnel
should be handling this equipment with
reference to the installation manual.
CAUTION This symbol shows that information is
available such as the operating manual or
installation manual.
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 11 21/01/2019 10:24
12
2. OPERATING INSTRUCTIONS
2.1. Product Description
control panel
upper air lter
(behind the grille)
upper air intake
drain outlet
air outlet
lower air lter
lower air intake
drain outlet
(only for pump
heating mode)
power cord buckle
power cord outlet
power plug socket
bottom tray
drain outlet
horizontal louver
blade
(swing automatically)
handle
(both sides)
panel
caster
front rear
2.2. Product usage
Warnings
Transport of equipment containing ammable refrigerants.
See transport regulations
Marking of equipment using signs.
See local regulations
Disposal of equipment using ammable refrigerants.
See national regulations.
Storage of equipment/appliances.
The storage of equipment should be in accordance with the
manufacturers instructions.
Storage of packed (unsold) equipment. Storage package protection
should be constructed such that mechanical damage to the equipment
inside the package will not cause a leak of the refrigerant charge.
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 12 21/01/2019 10:24
13
EN
Portable air conditioner | Aire acondicionado portátil | Ar Condicionado Portátil
The maximum number of pieces of equipment permitted to be
stored together will be determined by local regulations.
Information on servicing
1. Area checks
Prior to beginning work on systems containing ammable refrigerants,
safety checks are necessary to ensure that the risk of ignition is
minimised. For repair to the refrigerating system, the following
precautions shall be complied with prior to conducting work on the
system.
2. Work procedure
Works shall be undertaken under a controlled procedure so as to
minimise the risk of a ammable gas or vapour being present while the
work is being performed.
3. General work area
All maintenance sta and others working in the local area shall be
instructed on the nature of work being carried out. Work in conned
spaces shall be avoided. The area around the work space shall be
sectioned o. Ensure that the conditions within the area have been
made safe by control of ammable material.
4. Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector
prior to and during work, to ensure the technician is aware of
potentially ammable atmospheres. Ensure that the leak detection
equipment being used is suitable for use with ammable refrigerants,
i.e. no sparking, adequately sealed or intrinsically safe.
5. Presence of re extinguisher
If any hot work is to be conducted on the refrigeration equipment or
any associated parts, appropriate re extinguishing equipment shall be
available on hand. Have a dry power or CO2 re extinguisher next to
the charging area.
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 13 21/01/2019 10:24
14
6. No ignition sources
No person carrying out work with a refrigeration system which involves
exposing any pipe work that contains or has contained ammable
refrigerant shall use any sources of ignition in such a manner that
it may lead to risk of re or explosion. All possible ignition sources,
including cigarette smoking, should be kept suiciently far away from
the site of installation, repairing, removing and disposal, during which
ammable refrigerant can possibly be released to the surrounding
space. Prior to work taking place, the area around the equipment is
to be surveyed to make sure that there are no ammable hazards or
ignition risks. “NO SMOKING” signs shall be displayed.
7. Ventilated area
Ensure the work area is in the open or that it is adequately ventilated
before breaking into the system or conducting any hot work. A degree
of ventilation shall continue during the period that the work is carried
out. The ventilation should safely disperse any released refrigerant and
preferably expel it externally into the atmosphere.
8. Checks to the refrigeration equipment
Where electrical components are being changed, they shall be t
for the purpose and to the correct specication. At all times the
manufacturers maintenance and service guidelines shall be followed.
If in doubt, consult the manufacturer’s technical department for
assistance. The following checks shall be applied to installations using
ammable refrigerants:
the charge size is in accordance with the room size within which the
refrigerant containing parts are installed;
the ventilation machinery and outlets are operating adequately and
are not obstructed;
if an indirect refrigerating circuit is being used, the secondary
circuits shall be checked for the presence of refrigerant; marking to
the equipment continues to be visible and legible.
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 14 21/01/2019 10:24
15
EN
Portable air conditioner | Aire acondicionado portátil | Ar Condicionado Portátil
marking and signs that are illegible shall be corrected;
refrigeration pipe or components are installed in a position where
they are unlikely to be exposed to any substance which may corrode
refrigerant containing components, unless the components are
constructed of materials which are inherently resistant to being
corroded or are suitably protected against being so corroded.
9. Checks to electrical devices
Repair and maintenance to electrical components shall include
initial safety checks and component inspection procedures. If a fault
exists that could compromise safety, then no electrical supply shall
be connected to the circuit until it is satisfactorily dealt with. If the
fault cannot be corrected immediately but it is necessary to continue
operation, and adequate temporary solution shall be used. This shall be
reported to the owner of the equipment, so all parties are advised.
Initial safety checks shall include:
that capacitors are discharged: this shall be done in a safe manner
to avoid possibility of sparking
that there no live electrical components and wiring are exposed
while charging, recovering or purging the system;
that there is continuity of earth bonding.
10. Repairs to sealed components
10.1 During repairs to sealed components, all electrical supplies shall
be disconnected from the equipment being worked upon prior to
any removal of sealed covers, etc. If it is absolutely necessary to
have an electrical supply to equipment during servicing, then a
permanently operating form of leak detection shall be located at
the most critical point to warn of a potentially hazardous situation.
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 15 21/01/2019 10:24
16
10.2 Particular attention shall be paid to the following to ensure that by,
working on electrical components, the casing is not altered in such
a way that the level of protection is aected. This shall include
damage to cables, excessive number of connections, terminals not
made to original specication, damage to seals, incorrect tting of
glands, etc.
Ensure that apparatus is mounted securely.
Ensure that seals or sealing materials have not degraded in such
a way that they no longer serve the purpose of preventing the
ingress of ammable atmospheres. Replacement parts shall be in
accordance with the manufacturer s specications.
Note
: the use of silicon sealant may inhibit the eectiveness of some
types of leak detection equipment. Intrinsically safe components do not
have to be isolated prior to working on them.
11. Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the
circuit without ensuring that this will not exceed the permissible
voltage and current permitted for the equipment in use. Intrinsically
safe components are the only types that can be worked on while live in
the presence of a ammable atmosphere. The test apparatus shall be
at the correct rating.
Replace components only with parts specied by the manufacturer.
Other parts may result in the ignition of refrigerant in the atmosphere
from a leak.
12. Cabling
Check that cabling will not be subject to wear, corrosion, excessive
pressure, vibration, sharp edges or any other adverse environmental
eects. The check shall also take into account the eects of aging or
continual vibration from sources such as compressors or fans.
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 16 21/01/2019 10:24
17
EN
Portable air conditioner | Aire acondicionado portátil | Ar Condicionado Portátil
13. Detection of ammable refrigerants
Under no circumstances shall potential sources of ignition be used
when in the search for or detection of refrigerant leaks. A halide torch
(or any other detector using a naked ame) shall not be used.
14. Leak detection methods
The following leak detection methods are deemed acceptable for
systems containing ammable refrigerants. Electronic leak detectors
shall be used to detect ammable refrigerants, but the sensitivity may
not be adequate, or may need re-calibration (detection equipment
shall be calibrated in a refrigerant-free area). Ensure that the detector
is not a potential source of ignition and is suitable for the refrigerant.
Leak detection equipment shall be set at a percentage of the LFL of
the refrigerant and shall be calibrated to the refrigerant employed and
the appropriate percentage of gas (25 % maximum) is conrmed. Leak
detection uids are suitable for use with most refrigerants but the use
of detergents containing chlorine shall be avoided as the chlorine may
react with the refrigerant and corrode the copper pipe-work.
If a leak is suspected, all naked ames shall be removed or
extinguished. If a leakage of refrigerant is found which requires brazing,
all of the refrigerant shall be recovered from the system, or isolated (by
means of shut o valves) in a part of the system remote from the leak.
Oxygen free nitrogen (OFN) shall then be purged through the system
both before and during the brazing process.
15. Removal and evacuation
When accessing the refrigerant circuit to make repairs for any
other purpose, conventional procedures shall be used. However,
it is important that best practice is followed since ammability is a
consideration. The following procedure shall be adhered to:
remove refrigerant;
purge the circuit with inert gas;
evacuate;
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 17 21/01/2019 10:24
18
purge again with inert gas;
open the circuit by cutting or brazing.
The refrigerant charge shall be recovered into the correct recovery
cylinders. The system shall be ushed with OFN to render the unit safe.
This process may need to be repeated several times. Compressed air
or oxygen shall not be used for this task.
Flushing shall be achieved by breaking the vacuum in the system with
OFN and continuing to ll it until the working pressure is achieved,
then venting to atmosphere, and nally pulling down to a vacuum. This
process shall be repeated until no refrigerant is in the system.
When the nal OFN charge is used, the system shall be vented down
to atmospheric pressure to enable work to take place. This operation is
absolutely vital if brazing operations on the pipe-work are to take place.
Ensure that the outlet for the vacuum pump is not closed to any
ignition sources and there is ventilation available.
16. Charging procedures
In addition to conventional charging procedures, the following
requirements shall be followed:
Ensure that contamination of dierent refrigerants does not occur
when using charging equipment. Hoses or lines shall be as short as
possible to minimize the amount of refrigerant contained in them.
Cylinders shall be kept upright.
Ensure that the refrigeration system is earthed prior to charging the
system with refrigerant.
Label the system when charging is complete (if not already).
Extreme care shall be taken not to overll the refrigeration system.
Prior to recharging the system it shall be pressure tested with OFN.
The system shall be leak tested on completion of charging but prior
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 18 21/01/2019 10:24
19
EN
Portable air conditioner | Aire acondicionado portátil | Ar Condicionado Portátil
to commissioning. A follow up leak test shall be carried out prior to
leaving the site.
17. Decommissioning
Before carrying out this procedure, it is essential that the technician
be completely familiar with the equipment and all its detail. It is
recommended good practice that all refrigerants are recovered safely.
Prior to the task being carried out, an oil and refrigerant sample shall
be taken.
In case analysis is required prior to re-use of reclaimed refrigerant.
It is essential that electrical power is available before the task is
commenced.
a) Become familiar with the equipment and its operation.
b) Isolate system electrically
c) Before attempting the procedure ensure that:
mechanical handling equipment is available, if required, for handling
refrigerant cylinders;
all personal protective equipment is available and being used
correctly;
the recovery process is supervised at all times by a competent
person;
recovery equipment and cylinders conform to the appropriate
standards.
d) Pump down refrigerant system, if possible.
e) If a vacuum is not possible, make a manifold so that refrigerant can
be removed from various parts of the system.
f) Make sure that cylinder is situated on the scales before recovery
takes place.
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 19 21/01/2019 10:24
20
g) Start the recovery machine and operate in accordance with
manufacturers instructions.
h) Do not overll the cylinders (no more than 80 % of the volume liquid
charge).
i) Do not exceed the maximum working pressure of the cylinder, even
temporarily.
j) When the cylinders have been lled correctly and the process
completed, make sure the cylinders and the equipment are removed
from the site promptly and all isolation valves on the equipment are
closed o.
k) Recovered refrigerant shall not be charged into another refrigeration
system unless it has been cleaned and checked.
18. Labelling
Equipment shall be labelled stating that it has been de-commissioned
and emptied of refrigerant. The label shall be dated and signed. Ensure
that there are labels on the equipment stating the equipment contains
ammable refrigerant.
19. Recovery
When removing refrigerant from a system, either for service
or decommissioning, it is recommended good practice that all
refrigerants be removed safely.
When transferring refrigerant into cylinders, ensure that only
appropriate refrigerant recovery cylinders are used. Ensure that the
correct numbers of cylinders for holding the total system charge are
available. All cylinders to be used are designated for the recovered
refrigerant and labelled for that refrigerant (i.e. special cylinders
for the recovery of refrigerant). Cylinders shall be complete with
pressure relief valve and associated shut-o valves in good working
order.
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 20 21/01/2019 10:24
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182

Becken AR COND PORTATIL 12000BTU BAC4255 Manual do proprietário

Categoria
Condicionadores de ar de sistema split
Tipo
Manual do proprietário