Ingersoll-Rand ARO 651763-EM-0 Manual do usuário

Tipo
Manual do usuário
47520296001
Edition F
February 2018
Save These Instructions
User Manual
Manuel d’utilisation
FR
Manual del Usuario
ES
User Manual
EN
Manual do Usuário
PT
Controller for Air Operated
Diaphragm Pumps
For the latest software updates and user manuals, visit http://www.arozone.com/controller-downloads.
2 47520296001_edF
1
DIN
M8
M8
M12
47520296001_edF 3
A = 20" (510 mm)
B = 14.5" (370 mm)
C = 4" (100 mm)
D = 2" (50 mm)
E = 5" (130 mm)
F = 12" (310 mm)
G = 5.9" (150 mm)
A
B
F
G
2
A
C
B
D
E
C
4 47520296001_edF
0.4 lb
(170 g)
0.67”
(17 mm)
2.93”
(74.5 mm)
M4 (#8)
x6
3
2.93”
(74.5 mm)
47520296001_edF 5
TB1
USB
1
0V
+ 24 V
LED1
RS485
+-
0V
1
TB3
1
TB4
K1
1 TB7 15
1
TB9
1 TB10
1
TB5
1
TB6
K2
1
TB8
15
1
TB11
1 TB12
6
1
TB2
9
4
6 47520296001_edF
DIN
6
7
4
5
M8
M8
M12
47520296001_edF 7
Batch A Batch B
6
Alarm Output
COM
N.O.
TB4
Digital Output
+24EN
GND
1
2
TB3
DI 1
GND
DI 2
GND
DI 3
GND
+ 24
DI 4
GND
+ 24
DI 5
GND
+ 24
DI 6
GND
345 6 7 8 9
10 11 12 13 14
15
Digital Input
TB7
4-20 mA Input
(for proportional mode)
+ 24
AI 1
GND
+ 24
AI 2
GND
12
34
5
6
TB9
4-20 mA Output
AO 1
GND
TB10
1
2
1
2
1
2
9
8 47520296001_edF
Batch A Batch B
7
Alarm Output
COM
N.O.
TB4
Digital Output
+24EN
GND
1
2
TB3
DI 1
GND
DI 2
GND
DI 3
GND
+ 24
DI 4
GND
+ 24
DI 5
GND
+ 24
DI 6
GND
345 6 7 8 9 10 11 12 13 14
15
Digital Input
TB7
4-20 mA Input
(for proportional mode)
+ 24
AI 1
GND
+ 24
AI 2
GND
1 2 345
6
TB9
4-20 mA Output
AO 1
GND
TB10
1
2
1
2
1
2
47520296001_edF 9
9
V1.0
V2.0
24 VDC
USB
Power In Emergency
Stop
GND
+
+
+
1
2
RS485
23
+24EN
+24
1
2
TB2
+24
GND
1
2
TB1
COM Port
DIN
M8
M8
M12
8
(for future use)
10 47520296001_edF
= 0.24" - 0.47" (6 - 12 mm)
< 0.24" (6 mm)
11
12
12
13
10
47520296001_edF 11
=
14
14
11
12
12 47520296001_edF
13
47520296001_edF 13
TYPE 4X
TYPE 4X
14
14 47520296001_edF
15
16
47520296001_edF 15
00:00:02
1
2
3
18
17
16 47520296001_edF
?
?
{
1
2
19
1
1
2
47520296001_edF 17
13
14
15
16
9
8 10
1
2
3
4
5
6
7
11
12
20
English Español Français Português
1 Power Alimentación Bouton d’Alimentation Potência
2 Start / Pause Arranque / Pausa Démarrer/Pause Liga/Desliga
3 Stop Parada Arrêt Parar
4 Left / Decrease Izquierda / Disminuir Gauche/Diminuer Esquerdo / Diminuir
5 Enter Entrar Entrée Enter
6 Next / Down Siguiente / Abajo Suivant/Bas Próximo / Baixo
7 Right / Increase Derecha / Aumentar Droite/Augmenter Direito / Aumentar
8 Previous / Up Anterior / Arriba Précédent/Haut Anterior / Cima
9 Navigate to Home Ir a Inicio Accueil Navegar para página inicial
10 Navigate to Previous Ir a Anterior Précédent Navegar para Anterior
11 Numerical Keypad Teclado Numérico Clavier Numérique Teclado Numérico
12 Back Space Retroceder Retour Arrière Retroceder
13 Buzzer Mute Silenciador del Zumbador Muet Campainha Silenciada
14 Pump / Flow Meter
Selection
Bomba / Medidor
de Flujo Selección
Pompe / Débitmètre
Sélection
Bomba / Medidor de
Cauda Seleção
15 Quick Start Arranque Rápido Démarrage Rapide Início Rápido
16 Pump LED Indicators Indicadores LED de la bomba Indicateurs LED de la
pompe
Indicadores LED da bomba
18 47520296001_edF
1
4
7
6
3
2
5
21
English Español Français Português
1 Current Screen Icon Ícono de la Pantalla Actual Icône de l’écran Aché Imagem da tela inicial
2 Available Choices Opciones Disponibles Choix Proposés Escolhas Disponíveis
3 Alarm Present Icon Ícono de Alarma Presente Icône de l’Alarme Activée Ícone de Alarme Atual
4 Pump Number Selected Número de Bomba Seleccionada Numéro de la Pompe
Sélectionnée
Número da Bomba Sele-
cionada
5 Pump Status Estado de la Bomba État de la Pompe Estado da Bomba
6 Currently Selected Choice Opción Seleccionada Actual-
mente
Choix Sélectionné Escolha Selecionada Atual
7 Current Screen Name Nombre de la Pantalla Actual Nom de l’écran Aché Nome da tela atual
47520296001_edF 19
Run Modes Active Alarms Setup
Batch Proportional
Manual
Batch A
Batch B
Batch C
Batch D
Batch E
Clear Alarms
Password
General Setup
Languages
English
Deutsch
Español
Français
Italiano
Português
Units
Gallons (gal)
Liters (L)
Pounds (lb)
Ounce (oz)
Kilograms (kg)
Cycles (cyc)
Contrast
Link P1 & P2
No Link
Batch A
Batch B
Batch C
Batch D
Batch E
Manual
About
Run Setup
Batch
Proportional
Manual
Pump Setup Change Password
Service
Totalizer
Service Interval
Signal Out
Calibration
Pressure Sensor
Proximity Sensor
Flow Meter
Pump Sensor
Alarm Setup
Shut Down Pump
Lost Prime
Leak Detect
Service Interval
Signal Range
Max Rate
Batch Complete
Remote Start 1
Batch A
Batch B
Batch C
Batch D
Batch E
Batch A
Batch B
Batch C
Batch D
Batch E
Remote Start 2
Batch A
Batch B
Batch C
Batch D
Batch E
Manual Calibration
Auto Calibration
New PWD
ARO Controller Menu Flow Chart
EN-2 47520296001_edF
EN
1. Introduction
The ARO Controller is capable of controlling upto two Electronic Interface Air Operated diaphragm pumps
independently or simultaneously. Each of the two pumps can be actuated in any of three modes: Manu-
al, Batch and Proportional each with specic process control capabilities. It can also output analog signals
representative of the speed of each of the pumps that can be used in other parts of the process for greater
automation possibilities.
The ARO Controller can also accept external signals, such as from uid levels, push buttons, analog sensors,
or even PLC signals, to automate pump start and stop per pre-programmed levels or specic control logic.
The ARO Controller can also detect abnormal or undesirable conditions and react to them, by either trigger-
ing an external alarm, stopping the pump or both. For emergency situations, it can also accept an Emergency
Stop signal that will stop both pumps immediately.
It features a durable membrane user interface with an LCD screen that makes interacting with the unit very
easy, and its programming is based on a very intuitive menu logic. Its plastic housing is rated NEMA 4X for
hermeticity.
The version 2.0 software for the ARO controller can control a ow meter which measures the ow inde-
pendently or simultaneously. The function of the ow meter is designed to connect with the standard PD
pump without an EOS or the solenoid input. The ARO Controller is capable of connecting/controlling two
ow meters.
NOTE: The ARO controller can operate with one pump or two pumps simultaneously, with one ow meter
or two ow meters simultaneously, but will not operate with one pump and one ow meter simultaneously.
2. Setup
The Setup menu features a number of options to modify the controller’s general behaviour (General Setup),
program specic pump run modes (Run Setup), and specify general pump behaviours (Pump Setup).
The Setup menu is password protected. To exit the password-protected menu, press “NAVIGATE TO
PREVIOUS” enough times to exit the Setup menu; press “NAVIGATE TO HOME”, or leave the controller
unattended. After 10 minutes of no key strokes on the keyboard the controller will automatically exit the
password protected menu. If the screen shows a pump that is running, the screen will change to the
equivalent running mode screen outside the password-protected menu. In all other cases, the controller will
exit to the Home screen.
On the Home screen, select the “Setup and press ENTER.
On the “Password” screen, press ENTER and then type the password: 27632.
Press ENTER again.
When the correct password is entered the Setup screen is displayed.
If a wrong password is typed, an alert message is displayed. Select “Password” and
press ENTER to type the correct password.
NOTE: If the user forgets the password, the software must be installed again. Refer
to section 4.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100

Ingersoll-Rand ARO 651763-EM-0 Manual do usuário

Tipo
Manual do usuário