Becken AR CONDICIONADO INVERTER I 12BTU Manual do proprietário

Categoria
Condicionadores de ar de sistema split
Tipo
Manual do proprietário
Split Air Conditioner
Model: I 9 BTUI 12 BTU
Instruction Manual
Dear client,
We thank you for purchasing this product.
This appliance was submitted to several laboratorial tests, which certify its
quality. To simplify the use of this appliance, this instruction manual has been
provided. The instructions must ensure a quick and safe use.
Please read carefully the instructions and safety measures described in this
manual.
We wish our clients great satisfaction in using their new appliance.
2
Index
1. Safety Instructions.......................................................................................... 5
1.1. Power Energy .......................................................................................... 6
1.2. Power Cord and Other Cables................................................................. 6
1.3. Humidity and Water ................................................................................. 6
1.4. Cleaning................................................................................................... 6
1.5. General Precautions ................................................................................ 7
2. Utilization and Functioning ........................................................................... 13
2.1. Product Description................................................................................ 13
2.2. Remote Control...................................................................................... 14
2.2.1. Remote Control Operation .............................................................. 15
2.2.2. Replacing the Batteries on the Remote Control .............................. 17
2.3. Working Principle and Special Functions............................................... 18
2.3.1. Special Functions for Cooling.......................................................... 18
2.3.2. Special Functions for Heating.......................................................... 19
2.3.3. Anti-Cool Wind Function.................................................................. 19
2.4. Installation.............................................................................................. 20
2.4.1. Installation Diagram......................................................................... 20
2.4.2. Installation Site Instructions............................................................. 21
2.4.2.1. Indoor Unit Installation Site ................................................... 21
2.4.2.2. Outdoor Unit Installation Site................................................. 21
3
2.4.3. Earthing Requirements.................................................................... 22
2.4.4. Indoor Unit Installation..................................................................... 23
2.4.4.1. Rear Panel Installation .......................................................... 23
2.4.4.2. Piping Hole Installation.......................................................... 23
2.4.4.3. Water Drain Pipe Installation................................................. 23
2.4.4.4. Connect the Indoor and Outdoor Electric Wires .................... 24
2.4.4.5. Installing the Indoor Unit........................................................ 25
2.4.4.6. Connection Pipe Installation.................................................. 26
2.4.5. Outdoor Unit Installation.................................................................. 26
2.4.5.1. Installing the Outdoor Unit..................................................... 26
2.4.5.2. Air Purging and Leakage Test............................................... 27
2.4.5.3. Outdoor Condensation Drainage (Only for Heat Pump Unit). 28
2.5. Check After Installation and Operation Test .......................................... 28
2.6. Emergency Operation............................................................................ 29
2.7. Connection Pipe and Additional Volume of Refrigerant ......................... 30
3. Care and Maintenance ............................................................................... ..32
4. Troubleshooting.......................................................................................... ..34
5. Aftermarket................................................................................................. ..38
6. Environment Conservation ........................................................................... 39
4
1. Safety Instructions
ATTENTION
Risk of Electric Shock
Do Not Open
Attention: to avoid the risk of electric shock, do not
remove the cover. The interior does not contain any
parts that may be repaired by the user. Ask for
assistance to qualified personnel.
Important Warnings
Before using your appliance, read carefully this instruction manual and keep it in
a safe place, as you may need it for future consultations.
Before you start your appliance, and to ensure a correct use, do not use it if:
- It has fallen on the ground;
- You notice any evidence of damage;
- Any anomaly occurs during its operation;
To avoid hazards and deterioration of your appliance by an incorrect use, it is
advisable to read the instructions carefully and attentively.
Your appliance must not be used to other ends than the ones foreseen in the
instructions manual. Your safety is only guaranteed in a household use and not
for commercial use. The incorrect use will not be covered and automatically
cancels the right to warranty.
Assistance
Be sure that, in case of malfunction, you take your appliance to a qualified
technician for assistance.
5
This appliance can be used by children from 8 years old and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given instruction concerning use of the appliance in a
safe way and understand the hazards involved. Children shall
not play with the appliance. Cleaning and maintenance shall not
be made by children without supervision.
These instructions are also available on www.suporteworten.pt
1.1. Power Energy
Make sure the voltage of the electric network is compatible with the one of the
appliance. If it does not match, consult the vendor or Customer Support Service.
1.2. Power Cord and Other Cables
Do not roll up or pull the cord to disconnect the appliance, and do not use to
twine the appliance. Keep the cord far from warm surfaces.
Never use the appliance if it has a damaged cable or socket, or if it is not
working properly.
In case of damage of the power cord, do not use your appliance. Take it to
technical assistance for its replacement.
1.3. Humidity and Water
Do not use your appliance in humid places. Do not let your appliance to catch
water under any circumstance, as it may be dangerous. TO AVOID FIRE
HAZARD OR ELECTRIC SHOCK DO NOT EXPOSE YOUR APPLIANCE TO
HUMIDITY OR WATER. Do not place your appliance under water (for example
for washing).
1.4. Cleaning
Before cleaning, be sure to switch off the appliance and remove the plug from
the mains power supply.
Do not splash water on the units for cleaning, as electric shocks may occur.
Wipe the unit with a dry soft cloth or a cloth slightly moistened with water or
cleaner (not with a volatile liquid such as thinner or gasoline).
6
1.5. General Precautions
Please follow the instructions of the user manual, which helps properly
installing and operating this product and enjoying its advanced features.
Please keep the instructions for future reference.
Read all instructions before using the product.
Do not use the product if the supply cord is damaged. If it is the case, it
must be replaced by the manufacturer or its service agent.
The pictures in this manual may be different from the real product, please
refer to the real product for reference.
The symbol stands for the items that should be forbidden.
The symbol stands for the items or instructions that should be
followed.
When the voltage is very high, the components would be easily damaged.
When the voltage is very low, the compressor vibrates terribly and the
refrigerant system will be damaged. The compressor and electric
components cannot work and the voltage should be stable. There should
not exist a big fluctuation.
Be sure to pull out the power plug if the air conditioner is not going to be
used for a long time. Otherwise, the accumulated dusts may cause
overheating or fire.
Never splice the power cord or use an extended cord as it can cause
overheating or fire.
7
Do not leave windows and doors open for a long time while operating the
air conditioner as it can decrease the air conditioning capacity.
Do not block the air intake or outlet vents of both the outdoor and indoor
units as it can decrease the air conditioning capacity or cause a
malfunction.
The power supply must adopt the special circuit with air switch protection
and assure it has enough capacity. The unit will be turned on or off
according to your requirement automatically, please do not turn on or
turn off the unit frequently, otherwise disadvantage effect may be caused
to the unit.
When having a burning smell or smoke, please turn off the power supply
and contact with the service center. If the abnormity still exists, the unit
may be damaged, and may cause electric shock or fire.
8
Keep combustible spray away from the units more than 1m as it can
cause a fire or explosion.
Do not attempt to repair the air conditioner by yourself. The wrong repair
will lead to an electric shock or fire, so you should contact the service
center to repair.
Please do not cut off or damage the power cords and control cords. If
they are damaged, please ask the qualified personnel to change them.
To adjust the airflow direction appropriately, when operating the unit,
adjust the vertical and lateral airflow direction using the remote control.
Do not insert your hands into the air intake or outlet vents.
Swing louve
r
Guide louve
r
9
Do not blow the wind to animals and plants directly as it can cause a bad
effects on them.
Do not apply the cold wind to the body for a long time as it can cause
health problems.
Do not use the air conditioner for other purposes, such as drying clothes,
preserving foods, etc.
10
Splashing water on the air conditioner can cause an electric shock and
malfunction.
Do not place a heater or stove near the air conditioner.
The unit should be installed only by authorized service center according
to local or government regulations and in compliance with this manual.
Before installing, please contact with local authorized maintenance
center. If the unit is not installed by the authorized service center, the
malfunction may not be solved due to inconvenient contact between the
user and the service personnel.
When removing the unit to the other place, please firstly contact with the
local authorized service center.
11
Before obtaining access to terminals, all supply circuits must be
disconnected.
If the supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid a hazard.
The appliance must be positioned so that the plug is accessible.
The temperature of refrigerant line will be high. Please keep the
interconnection cable away from the copper tube.
Children should be supervised to ensure that they do not play with the
appliance.
A dedicated power supply circuit should be used in accordance with local
electrical safety regulations.
Do not drag the power cord with excessive force.
The unit should be reliably earthed and connected to an exclusive earth
device by professionals.
The air switch must have the functions of magnetic tripping and heat
tripping to prevent short circuit and overload.
The minimum distance between the unit and combustive surface is 1.5m.
The appliance shall be installed in accordance with national wiring
regulations.
An all-pole disconnection switch with a contact separation of at least
3mm in all poles should be connected in fixed wiring.
Make sure the live wire, neutral wire and earth wire in the family power
socket are properly connected. There should be reliable circuit in the
diagram.
Inadequate or incorrect electrical connections may cause electric shock
or fire.
12
2. Utilization and Functioning
2.1. Product Description
1. Power Cable.
2. Front Panel.
3. Filter.
4. Back base.
5. Guide Louver.
6. Wall Pipe.
7. Bind Tape.
8. Drain Pipe.
9. Remote Control.
Indoor Unit
Outdoor Unit
Air In
Air Out
2
3
4
1
5
6
9
Air In
Air Out
7
8
13
2.2. Remote Control
12
3
4
56
7
8
9
10 11
12 13 14
1. On/Off: Press this button to start or stop
operation.
2. Mode: Press this button to select
operation mode (Auto / Cool / Dry / Fan /
Heat).
3. +: Press this button to increase the
temperature setting.
4. +: Press this button to decrease the
temperature setting.
5. Fan: Press this button to set fan speed
Louver.
6. : Press this button to set swing angle.
7. Timer On: Press this button to set auto
timer on.
8. Timer Off: Press this button to set auto
timer off.
9. Clock: Press this button to set clock.
10. X-Fan: Refer to section “2.2.1. Remote
Control Operation” (Note: X-Fan is the
alternative expression of Blow the easie
r
understanding).
11. Temp: Refer to section “2.2.1. Remote
Control Operation”.
12. Turbo: Refer to section “2.2.1. Remote
Control Operation”.
13. Sleep: Refer to section “2.2.1. Remote
Control Operation”.
14. Light: Press this button to turn the light
on/off.
15. Mode icon: If MODE button is pressed,
the current operation mode icon (Auto),
(Cool), (Dry), (Fan) or (Heat,
that is only for heat pump models) will show.
16. Sleep icon: is displayed by pressing
the Sleep button. Press this button again to
clear the display.
17. Temp icon: Pressing the Temp button,
(set temperature), (indoor room
temperature), (outdoor ambient
temperature) and blank is displayed
circularly.
18. Up and Down swing icon: is
displayed when pressing the up and down
swing button. Press this button again to
clear the display.
15
16
17 18 19
20
21
22
23
24
25
19. Light icon: is displayed by pressing the Light button. Press Light button again to
clear the display.
20. Lock icon: is displayed by pressing "+" and “-” buttons simultaneously. Press
them again to clear the display.
14
2.2.1. Remote Control Operation
1. On/Off button: Press this button to turn on the unit. Press this button again to
turn off the unit.
2. Mode button: Each time you press this button, one mode is selected in a
sequence that goes from Auto, Cool, Dry, Fan and Heat *, as the following:
*Note: Only for models with heating function.
After powering, the Auto mode is defaulted. In Auto mode, the set temperature
will not be displayed on the LCD, and the unit will automatically select the
suitable operation mode in accordance with the room temperature to make the
indoor room comfortable.
3. + button: Press this button to increase set temperature. Hold it down for
above 2 seconds to rapidly increase set temperature. In Auto mode, setting the
temperature is not adjustable.
4. – button: Press this button to decrease set temperature. Hold it down for
more than 2 seconds to rapidly decrease the set temperature. In Auto mode,
setting temperature is not adjustable.
5. Fan button: This button is used for setting fan speed in the sequence that
goes from Auto, , to and then back to Auto.
Low Speed, Medium Speed and High Speed
21. Set Time display: After pressing the Timer button, On or Off will blink. This area will
show the set time.
22. Turbo icon: is displayed when pressing the Turbo button. Press this button again
to clear the display.
23. Digital Display: This area will show the set temperature. In Save mode, "SE" will be
displayed. During defrosting operation, “H1” will be displayed.
24. X-Fan icon: is displayed when pressing the X-Fan button. Press this button again
to clear the display.
25. Fan Speed display: Press the Fan button to select the desired fan speed setting
(Auto, Low-Med-High).Your selection will be displayed in the LCD windows, except the
Auto fan speed.
A
uto Cool Dry Fan Heat
15
6. button: Press this button to set up and down swing angle, which circularly
changes as shown below:
This remote control is universal. If any command , or is sent out, the
unit will carry out the command as .
indicates the guide louver swings as:
7. Timer On button: Press this button to initiate the auto-ON timer. To cancel the
auto-timer program, simply press this button again.
After pressing this button, disappears and "On" blinks. 00:00 is displayed for
the On time setting. Within 5 seconds, press + or - button to adjust the time
value. Every press of either button changes the time setting by 1 minute.
Holding down either button rapidly changes the time setting by 1 minute and
then 10 minutes. Within 5 seconds after setting, press the Timer On button to
confirm.
8. Timer Off button: Press this button to initiate the auto timer off. To cancel the
auto-timer program, simply press the button again. The Timer Off setting is the
same as Timer On.
9. Clock button: Pressing the Clock button, the blinks. Within 5 seconds,
pressing + or - button adjusts the present time. Holding down either button for
more than 2 seconds increases or decreases the time by 1 minute every 0.5
second and then by 10 minutes every 0.5 second. During blinking after setting,
press the Clock button again to confirm the setting, and then will be
constantly displayed.
10. X- Fan button: Pressing the X -Fan button in Cool or Dry mode, the icon
is displayed and the indoor fan will continue operation for 10 minutes in order to
dry the indoor unit even though you have turned off the unit.
OFF
16
After powering, X-Fan Off is defaulted. X-Fan is not available in Auto, Fan or
Heat mode.
11. Temperature button: Press this button and you can select displaying the
indoor setting temperature or indoor ambient temperature. When the indoor unit
firstly power on it will display the setting temperature, if the temperature's
displaying status is changed from other status to " ", displays the ambient
temperature, 5s later or within 5s, it receives other remote control signal that will
return to display the setting temperature. If the users haven't set up the
temperature displaying status, that will display the setting temperature.
12. Turbo button: Press this button to activate/deactivate the Turbo function
which enables the unit to reach the preset temperature in the shortest time. In
Cool mode, the unit will blow strong cooling air at super high fan speed. In Heat
mode, the unit will blow strong heating air at super high fan speed (this function
is not applicable for some models).
13. Sleep button: Press this button to go into the Sleep operation mode. Press it
again to cancel this function. This function is available in Cool, Heat (only for
models with heating function) or Dry mode to maintain the most comfortable
temperature for you.
14. Light button: Press the Light button to turn on the display's light and press
this button again to turn off the display's light. If the light is turned on, is
displayed. If the light is turned off, disappears.
15. Lock button (combination of “+” and “-“ buttons): Press "+ " and "-" buttons
simultaneously to lock or unlock the keypad. If the remote control is locked,
is displayed. In this case, if you press any button, blinks three times.
16. Switching between Fahrenheit and Centigrade (combination of Mode and “-
“ buttons): When the unit is Off, press "Mode" and "- " buttons simultaneously to
switch between ˚C and ˚F.
2.2.2. Replacing the Batteries on the Remote Control
1. Remove the battery cover plate from the rear of the remote control (as shown
in the picture).
2. Take out the old batteries.
17
3. Insert two new AAA1.5V dry batteries, and pay attention to the polarity.
4. Reinstall the battery cover plate.
Notes:
When replacing the batteries, do not use old or different types of
batteries. Otherwise, it may cause malfunction.
If the remote control will not be used for a long time, please remove
batteries to prevent batteries from leaking.
The operation should be performed in its receiving range.
You should keep 1m away from the TV set or stereo sound sets.
If the remote control does not operate normally, please take the batteries
out and reinsert them after 30 seconds. If it still cannot operate properly,
replace the batteries.
2.3. Working Principle and Special Functions
2.3.1. Special Functions for Cooling
Air conditioner absorbs heat in the room and transmits to outdoor and
discharged, so that indoor ambient temperature decreased, its cooling capacity
will increase or decrease by outdoor ambient temperature.
Anti-freezing function:
If the unit is running in Cool mode and in low temperature, there will be frost
formed on the heat exchanger, when indoor heat exchanger temperature
18
decreased below 0˚C, the indoor unit microcomputer will stop compressor
running and protect the unit.
2.3.2. Special Functions for Heating
Air conditioner absorbs heat from outdoor and transmits to indoor, in this way to
increase room temperature. This is the heat pump heating principle, its heating
capacity will be reduced due to outdoor temperature decrease.
If the outdoor temperature becomes very low, please operate with other heating
equipments.
Defrosting:
When the outdoor temperature is low but with high humidity, after a long while
running, frost will form on outdoor unit and that will affect the heating effect. At
this time, the auto defrosting function will act, the heat running will stop for 8-
10mins.
During the auto defrosting, the fan motors of indoor unit and outdoor unit will
stop.
During the defrosting, the indoor indicator flashes, the outdoor unit may emit
vapor.
This is due to the defrosting, it isn't malfunction.
After defrosting is finished, the heating will recover automatically.
2.3.3. Anti-Cool Wind Function
In Heat mode, under the following three kinds of state, if the indoor heat
exchanger does not reach a certain temperature, the indoor fan will not act in
order to prevent cool wind blowing (within 2 minutes):
1. Heating starts.
2. After Auto Defrost is finished.
3. Heating under the low temperature.
Working temperature range
Indoor side DB/WB(˚C) Outdoor side DB/WB(˚C)
Maximum cooling 32/23 43/26
Minimum cooling 21/15 21/-
19
Maximum heating 27/- 24/18
Minimum heating 20/- -5/-6
The operating temperature range (outdoor temperature) for the cooling unit is -
7˚C 43˚C. For the cooling and heating units is -7~43˚C.
2.4. Installation
2.4.1. Installation Diagram
Space to the ceiling
Above
15cm
300cm 250
cm
15cm 15cm
50
cm
Above
Above
Above
Air outlet side
Space to the
wall
Above
Space to the
floor
These are the
dimensions of the space
necessary for a correct
installation of the
appliance including the
minimum permissible
distances to adjacent
structures.
50 cm
30 cm
30 cm
200 cm
Above
Above
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132

Becken AR CONDICIONADO INVERTER I 12BTU Manual do proprietário

Categoria
Condicionadores de ar de sistema split
Tipo
Manual do proprietário