SICK WLD16 Instruções de operação

Tipo
Instruções de operação
O P E R A T I N G I N S T R U C T I O N S
WLD16
O P E R A T I N G I N S T R U C T I O N S
WLD16
de
en
es
fr
it
ja
pt
ru
zh
Described product
W16
WLD16
Manufacturer
SICK AG
Erwin-Sick-Str. 1
79183 Waldkirch
Germany
Legal information
This work is protected by copyright. Any rights derived from the copyright shall be
reserved for SICK AG. Reproduction of this document or parts of this document is
only permissible within the limits of the legal determination of Copyright Law. Any modi‐
fication, abridgment or translation of this document is prohibited without the express
written permission of SICK AG.
The trademarks stated in this document are the property of their respective owner.
© SICK AG. All rights reserved.
Original document
This document is an original document of SICK AG.
2006/42/EC
NO
SAFETY
2
8020352.19RH / 15.01.2021 | SICK
Subject to change without notice
Contents
1 Safety information............................................................................ 4
1.1 General safety notes................................................................................ 4
1.2 Notes on UL approval............................................................................... 4
2 Intended use...................................................................................... 4
3 Operating and status indicators...................................................... 4
4 Mounting............................................................................................. 5
5 Electrical installation........................................................................ 5
6 Additional functions.......................................................................... 7
7 Commissioning.................................................................................. 7
7.1 Alignment.................................................................................................. 7
7.2 Check the application conditions............................................................ 8
8 Troubleshooting................................................................................. 9
9 Disassembly and disposal............................................................... 10
10 Maintenance...................................................................................... 10
11 Technical data.................................................................................... 10
11.1 Dimensional drawings.............................................................................. 11
CONTENTS
8020352.19RH / 15.01.2021 | SICK
Subject to change without notice
3
1 Safety information
1.1 General safety notes
Read the operating instructions before commissioning.
Connection, mounting, and configuration may only be performed by trained
specialists.
2006/42/EC
NO
SAFETY
Not a safety component in accordance with the EU Machinery Directive.
Do not install the sensor at locations that are exposed to direct sunlight
or other weather influences, unless this is expressly permitted in the operating
instructions.
These operating instructions contain information required during the life cycle of
the sensor.
1.2 Notes on UL approval
The device shall be supplied from an isolating transformer having a secondary overcur‐
rent protective device that complies with UL 248 to be installed in the field rated either:
a) max 5 amps for voltages 0 ~ 20 V (0 ~ 28.3 V peak), or
b) 100 / Vp for voltages of 20 ~ 30 V (28.3 ~ 42.4 V peak).
Alternatively, they can be supplied from a Class 2 power supply.
UL Environmental Rating: Enclosure type 1
2 Intended use
The WLD16 is an opto-electronic photoelectric retro-reflective sensor (referred to as
“sensor” in the following) for the optical, non-contact detection of objects, animals, and
persons. A reflector is required for it to function. If the product is used for any other
purpose or modified in any way, any warranty claim against SICK AG shall become void.
3 Operating and status indicators
1
2
1
LED indicator yellow: status of received light beam
2
LED indicator green: supply voltage active
1 SAFETY INFORMATION
4
8020352.19RH / 15.01.2021 | SICK
Subject to change without notice
4 Mounting
Mount the sensor and the reflector using suitable mounting brackets (see the SICK
range of accessories). Align the sensor and reflector with each other.
Note the sensor’s maximum permissible tightening torque of < 1,3 Nm.
5 Electrical installation
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
Male connector connection: Note pin assignment.
Cable: wire color
Only supply/switch on the voltage once all electrical connections have been estab‐
lished.
Explanations on connection diagram:
Alarm = alarm output
Health = alarm output
MF (pin 2 configuration) = external input, teach-in, switching signal
Q
L1
/C = switching output, IO-Link communication
Test = test input
U
B
: 10 ... 30 V DC
Table 1: Connections
Table 2: WLD, DC
WLD16x-
Push-pull x4112xxxZZZ xH112xxxZZZ x4111xxxZZZ xH111xxxZZZ
PNP x4812xxxZZZ xH812xxxZZZ x4811xxxZZZ xH811xxxZZZ
1 + (L+)
2
Q Q
Q Q
3 - (M)
4 Q Q
Q Q
1
2
4 3
1 = brn
2 = wht
3 = blu
4 = blk
0.14 mm
2
AWG26
1
2
4 3
1 = brn
2 = wht
3 = blu
4 = blk
0.14 mm
2
AWG26
MOUNTING 4
8020352.19RH / 15.01.2021 | SICK
Subject to change without notice
5
Table 3: DC
WLD16x-
Push-pull x4115xx
xZZZ
xH115xx
xZZZ
x4113xx
xZZZ
xH113xx
xZZZ
x4116xx
xZZZ
xH116xx
xZZZ
x4114xx
xZZZ
xH114xx
xZZZ
PNP x4815xx
xZZZ
xH815xx
xZZZ
x4813xx
xZZZ
xH813xx
xZZZ
x4816xx
xZZZ
xH816xx
xZZZ
x4814xx
xZZZ
xH814xx
xZZZ
1 + (L+)
2 Alarm Alarm Alarm Alarm Health Health Health Health
3 - (M)
4 Q Q
Q Q
Q Q
Q Q
1
2
4 3
1 = brn
2 = wht
3 = blu
4 = blk
0.14 m
m
2
AWG26
1
2
4 3
1 = brn
2 = wht
3 = blu
4 = blk
0.14 m
m
2
AWG26
1
2
4 3
1 = brn
2 = wht
3 = blu
4 = blk
0.14 m
m
2
AWG26
1
2
4 3
1 = brn
2 = wht
3 = blu
4 = blk
0.14 m
m
2
AWG26
Table 4: Push-pull, PNP, NPN
Push-pull
PNP
NPN
+ (L+)
Q ≤ 100 mA
‒ (M)
Push-pull
PNP
NPN
+ (L+)
Q ≤ 100 mA
‒ (M)
Push-pull
PNP
NPN
+ (L+)
Q ≤ 100 mA
‒ (M)
Push-pull
PNP
NPN
+ (L+)
Q ≤ 100 mA
‒ (M)
5 ELECTRICAL INSTALLATION
6
8020352.19RH / 15.01.2021 | SICK
Subject to change without notice
6 Additional functions
Alarm
Alarm output: The sensor (WLD16) features a pre-failure notification output (“Alarm” in
connection diagram [see table 2]), which issues a notification if the sensor is only ready
for operation to a limited extent. The LED flashes in this case. Possible causes: Sensor
is contaminated, sensor is out of alignment. In the good state: LOW (0), if excessively
contaminated HIGH (1).
Health output: The sensor (WLD16) features a pre-failure notification output (“Health”
in connection diagram [see table 2]), which issues a notification if the sensor is only
ready for operation to a limited extent or the cable has been interrupted. Possible
causes: Sensor or reflector is contaminated, sensor is out of alignment, cable is dam‐
aged. In the good state: HIGH (1), if excessively contaminated or in the event of cable
interruption LOW (0). The yellow LED indicator flashes in this case.
Table 5: Alarm / Health
Alarm ( 100 mA) Health (100 mA)
+ (L+)
Alarm
‒ (M)
+ (L+)
Alarm
‒ (M)
7 Commissioning
7.1 Alignment
Align the sensor with a suitable reflector. Select the position so that the red emitted
light beam hits the center of the reflector. The sensor must have a clear view of the
reflector, with no object in the path of the beam [see figure 1]. You must ensure that the
optical openings of the sensor and reflector are completely clear.
ADDITIONAL FUNCTIONS 6
8020352.19RH / 15.01.2021 | SICK
Subject to change without notice
7
Figure 1: Alignment
7.2 Check the application conditions
Adjust the distance between the sensor and the reflector according to the correspond‐
ing diagram [see table 6] (x = sensing range, y = operating reserve).
Table 6: Application conditions
0
100
10
1
Operating reserve
4
3
1
7
6
5
2
4
(13.12)
8
(26.25)
12
(39.37)
16
(52.49)
Distance in m (feet)
Sensing range
WLD16P-xxxxx1xx
Figure 2: Characteristic line 1
1
Reflector PL22
2
Reflector P250
3
Reflector PL20A
4
Reflector PL30A
5
Reflector PL40A
6
Reflector C110
7
Reflector PL80A
0
0.3 4
6
0.25 8
12
0.25 8
12
0.25 4
6
0.25 8
12
0.25 10
14
0.25 10
14
1
2
3
4
5
6
7
Sensing range
Distance in m (feet)
Sensing range max.
4
(13.12)
8
(26.25)
12
(39.37)
16
(52.49)
Figure 3: Bar graph 1
7 COMMISSIONING
8
8020352.19RH / 15.01.2021 | SICK
Subject to change without notice
0
100
10
1
2
3
4
1
Operating reserve
4
(13.12)
8
(26.25)
12
(39.37)
16
(52.49)
Distance in m (feet)
Sensing range
WLD16P-xxxxx1xx
Figure 4: Characteristic line 2
1
Reflector PL20 CHEM
2
Reflector PL250 CHEM
3
Reflector P250H
4
Reflector PL40 Antifog
0
0.25 3
5
0.25 8
12
0.25 5
7
1
2
3
4
Sensing range
Distance in m (feet)
Sensing range max.
4
(13.12)
8
(26.25)
12
(39.37)
16
(52.49)
0.25 6
9
Figure 5: Bar graph 2
0
100
10
1
WLD16P-xxxxx1xx
2
(6.56)
6
(19.69)
10
(32.81)
Operating reserve
Distance in m (feet)
Sensing range
4
(13.12)
8
(26.25)
Figure 6: Characteristic line 3
1
REF-IRF (50x70 mm)
0
0.3 3
4.5
1
Sensing range
Distance in m (feet)
Sensing range max.
2
(6.56)
4
(13.12)
6
(19.69)
1
(3.28)
3
(9.84)
5
(16.4)
Figure 7: Bar graph 3
8 Troubleshooting
The Troubleshooting table indicates measures to be taken if the sensor stops working.
LED indicator/fault pattern Cause Measures
Switching outputs do not
behave in accordance with
table 4
1. Change of the configuration
2. Short-circuit
1. Adjustment of the configura‐
tion
2. Check electrical connections
Yellow LED flashes Distance between sensor
and reflector is too large /
light beam is not completely
aligned to the reflector /
reflector is not suitable / Front
screen and/or reflector is con‐
taminated.
Check sensing range / check
alignment / SICK reflector is
recommended / Cleaning of
the optical surfaces (sensor
and reflector).
TROUBLESHOOTING 8
8020352.19RH / 15.01.2021 | SICK
Subject to change without notice
9
9 Disassembly and disposal
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE: This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
10 Maintenance
SICK sensors are maintenance-free.
We recommend doing the following regularly:
Clean the external lens surfaces
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
11 Technical data
WLD16P
Sensing range (with reflector PL80A) 0.25 m ... 10 m
Light spot diameter/distance Ø 60 mm (5 m)
Supply voltage U
B
DC 10 ... 30 V
Ripple 5 V
SS
Current consumption ≤ 30 mA
1)
< 50 mA
2)
Output current I
max.
≤ 100 mA
Max. response time ≤ 500 μs
3)
Switching frequency 1,000 Hz
4)
Enclosure rating
5)
see table 1:
x4, xH, x5, xI: IP66, IP67, IP69
6)
x9, xB: IP65
Protection class III
Circuit protection A, B, C, D
7)
9 DISASSEMBLY AND DISPOSAL
10
8020352.19RH / 15.01.2021 | SICK
Subject to change without notice
WLD16P
Ambient operating temperature –40 °C ... +60 °C
8)
1)
16 VDC to 30 VDC, without load
2)
10 VDC to 16 VDC, without load
3)
Signal transit time with resistive load
4)
With a light/dark ratio of 1:1.
5)
Pursuant to EN 60529
6)
Replaces IP69 K pursuant to ISO 20653: 2013-03
7)
A = U
B
-connections reverse polarity protected
B = inputs and output reverse-polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
8)
Do not bend cables below 0°C.
11.1 Dimensional drawings
4
3
2
1
Ø 4.1 (0.16)
7.2 (0.28)
39.9 (1.57)
55.4 (2.18)
55.7 (2.19)
8.7
(0.34)
21.8
(0.86)
45.5 (1.79)
5 (0.2)
29.9 (0.18)
6
(0.24)
3 (0.12)
15 (0.59)
27.8 (1.09)
7.7
(0.3)
35.5 (1.4)
4.1 (0.16)
42 (1.65)
7.8
(0.31)
20 (0.79)
6.5 (0.26)
Ø 12.9
(0.51)
8.3
(0.33)
5
Figure 8: Dimensional drawing 1, cable
1
Center of optical axis, sender
2
Center of optical axis, receiver
3
Fixing hole, Ø 4.1 mm
4
Connection
5
Display and setting elements
M12
4
3
2
1
18
(0.71)
Ø 4.1 (0.16)
7 (0.28)
39.9 (1.57)
55.4 (2.18)
55.7 (2.19)
8.7
(0.34)
21.8
(0.86)
45.5 (1.79)
5 (0.2)
29.9 (0.18)
52.9 (2.08)
6
(0.24)
3 (0.12)
15 (0.59)
28 (1.1)
7.5
(0.3)
35.5 (1.4)
4.1 (0.16)
42 (1.65)
17.5
(0.69)
20 (0.79)
6.5 (0.26)
5
Figure 9: Dimensional drawing 2, male con‐
nector
TECHNICAL DATA 11
8020352.19RH / 15.01.2021 | SICK
Subject to change without notice
11
B E T R I E B S A N L E I T U N G
WLD16
de
en
es
fr
it
ja
pt
ru
zh
Beschriebenes Produkt
W16
WLD16
Hersteller
SICK AG
Erwin-Sick-Str. 1
79183 Waldkirch
Deutschland
Rechtliche Hinweise
Dieses Werk ist urheberrechtlich geschützt. Die dadurch begründeten Rechte bleiben
bei der Firma SICK AG. Die Vervielfältigung des Werks oder von Teilen dieses Werks
ist nur in den Grenzen der gesetzlichen Bestimmungen des Urheberrechtsgesetzes
zulässig. Jede Änderung, Kürzung oder Übersetzung des Werks ohne ausdrückliche
schriftliche Zustimmung der Firma SICK AG ist untersagt.
Die in diesem Dokument genannten Marken sind Eigentum ihrer jeweiligen Inhaber.
© SICK AG. Alle Rechte vorbehalten.
Originaldokument
Dieses Dokument ist ein Originaldokument der SICK AG.
2006/42/EC
NO
SAFETY
8020352.19RH / 15.01.2021 | SICK
Subject to change without notice
13
Inhalt
12 Zu Ihrer Sicherheit............................................................................. 15
12.1 Allgemeine Sicherheitshinweise.............................................................. 15
12.2 Hinweise zur UL Zulassung...................................................................... 15
13 Bestimmungsgemäße Verwendung............................................... 15
14 Bedien- und Anzeigeelemente........................................................ 15
15 Montage.............................................................................................. 16
16 Elektrische Installation..................................................................... 16
17 Zusatzfunktionen.............................................................................. 18
18 Inbetriebnahme................................................................................. 18
18.1 Ausrichtung............................................................................................... 18
18.2 Einsatzbedingungen prüfen..................................................................... 19
19 Störungsbehebung............................................................................ 20
20 Demontage und Entsorgung............................................................ 21
21 Wartung.............................................................................................. 21
22 Technische Daten.............................................................................. 21
22.1 Maßzeichnungen...................................................................................... 22
INHALT
14
8020352.19RH / 15.01.2021 | SICK
Subject to change without notice
12 Zu Ihrer Sicherheit
12.1 Allgemeine Sicherheitshinweise
Lesen Sie vor der Inbetriebnahme des Geräts die Betriebsanleitung.
Der Anschluss, die Montage und die Konfiguration des Geräts dürfen nur
von geschultem Fachpersonal vorgenommen werden.
2006/42/EC
NO
SAFETY
Bei diesem Gerät handelt es sich um kein sicherheitsgerichtetes Bauteil im
Sinne der EU-Maschinenrichtlinie.
Installieren Sie den Sensor nicht an Orten, die direkter Sonneneinstrahlung
oder sonstigen Wettereinflüssen ausgesetzt sind, ausser dies ist in der Betriebs‐
anleitung ausdrücklich erlaubt.
Die vorliegende Betriebsanleitung enthält Informationen, die während des Lebens‐
zyklus der Lichtschranke benötigt werden.
12.2 Hinweise zur UL Zulassung
The device shall be supplied from an isolating transformer having a secondary overcur‐
rent protective device that complies with UL 248 to be installed in the field rated either:
a) max 5 amps for voltages 0 ~ 20 V (0 ~ 28.3 V peak), or
b) 100 / Vp for voltages of 20 ~ 30 V (28.3 ~ 42.4 V peak).
Alternatively, they can be supplied from a Class 2 power supply.
UL Environmental Rating: Enclosure type 1
13 Bestimmungsgemäße Verwendung
Die WLD16 ist eine optoelektronische Reflexions-Lichtschranke (im Folgenden Sensor
genannt) und wird zum optischen, berührungslosen Erfassen von Sachen, Tieren und
Personen eingesetzt. Zur Funktion wird ein Reflektor benötigt. Bei jeder anderen
Verwendung und bei Veränderungen am Produkt verfällt jeglicher Gewährleistungsan‐
spruch gegenüber der SICK AG.
14 Bedien- und Anzeigeelemente
1
2
1
Anzeige-LED gelb: Status Lichtempfang
2
Anzeige-LED grün: Betriebsspannung aktiv
ZU IHRER SICHERHEIT 12
8020352.19RH / 15.01.2021 | SICK
Subject to change without notice
15
15 Montage
Sensor und Reflektor an geeignete Befestigungswinkel montieren (siehe SICK-Zube‐
hör-Programm). Sensor und Reflektor zueinander ausrichten.
Maximal zulässiges Anzugsdrehmoment des Sensors von < 1,3 Nm beachten.
16 Elektrische Installation
Anschluss der Sensoren muss spannungsfrei erfolgen. Je nach Anschlussart sind die
folgenden Informationen zu beachten:
Steckeranschluss: Pinbelegung beachten.
Leitung: Adernfarbe
Erst nach Anschluss aller elektrischen Verbindungen die Spannungsversorgung anlegen
bzw. einschalten.
Erläuterungen zum Anschlussschema:
Alarm = Alarmausgang
Health = Alarmausgang
MF (Pin-2-Konfiguration) = Externer Eingang, Teach-in, Schaltsignal
Q
L1
/C = Schaltausgang, IO-Link Kommunikation
Test = Testeingang
U
B
: 10 ... 30 V DC
Tabelle 7: Anschlüsse
Tabelle 8: WLD, DC
WLD16x-
Push-pull x4112xxxZZZ xH112xxxZZZ x4111xxxZZZ xH111xxxZZZ
PNP x4812xxxZZZ xH812xxxZZZ x4811xxxZZZ xH811xxxZZZ
1 + (L+)
2
Q Q
Q Q
3 - (M)
4 Q Q
Q Q
1
2
4 3
1 = brn
2 = wht
3 = blu
4 = blk
0.14 mm
2
AWG26
1
2
4 3
1 = brn
2 = wht
3 = blu
4 = blk
0.14 mm
2
AWG26
15 MONTAGE
16
8020352.19RH / 15.01.2021 | SICK
Subject to change without notice
Tabelle 9: DC
WLD16x-
Push-pull x4115xx
xZZZ
xH115xx
xZZZ
x4113xx
xZZZ
xH113xx
xZZZ
x4116xx
xZZZ
xH116xx
xZZZ
x4114xx
xZZZ
xH114xx
xZZZ
PNP x4815xx
xZZZ
xH815xx
xZZZ
x4813xx
xZZZ
xH813xx
xZZZ
x4816xx
xZZZ
xH816xx
xZZZ
x4814xx
xZZZ
xH814xx
xZZZ
1 + (L+)
2 Alarm Alarm Alarm Alarm Health Health Health Health
3 - (M)
4 Q Q
Q Q
Q Q
Q Q
1
2
4 3
1 = brn
2 = wht
3 = blu
4 = blk
0.14
mm
2
AWG26
1
2
4 3
1 = brn
2 = wht
3 = blu
4 = blk
0.14
mm
2
AWG26
1
2
4 3
1 = brn
2 = wht
3 = blu
4 = blk
0.14
mm
2
AWG26
1
2
4 3
1 = brn
2 = wht
3 = blu
4 = blk
0.14
mm
2
AWG26
Tabelle 10: Push-pull, PNP, NPN
Push-pull
PNP
NPN
+ (L+)
Q ≤ 100 mA
‒ (M)
Push-pull
PNP
NPN
+ (L+)
Q ≤ 100 mA
‒ (M)
Push-pull
PNP
NPN
+ (L+)
Q ≤ 100 mA
‒ (M)
Push-pull
PNP
NPN
+ (L+)
Q ≤ 100 mA
‒ (M)
ELEKTRISCHE INSTALLATION 16
8020352.19RH / 15.01.2021 | SICK
Subject to change without notice
17
17 Zusatzfunktionen
Alarm
Alarmausgang: Der Sensor (WLD16) verfügt über einen Vorausfallmeldeausgang
("Alarm" im Anschlussschema [siehe Tabelle 2]) der meldet, wenn der Sensor nur noch
eingeschränkt betriebsbereit ist. Dabei blinkt die Anzeige-LED. Mögliche Ursachen: Ver‐
schmutzung des Sensors, Sensor ist dejustiert. Im Gutzustand: LOW (0), bei zu starker
Verschmutzung HIGH (1).
Health-Ausgang: Der Sensor (WLD16) verfügt über einen Vorausfallmeldeausgang
("Health" im Anschlussschema [siehe Tabelle 2]), der meldet, wenn der Sensor nur
noch eingeschränkt betriebsbereit ist oder die Leitung unterbrochen ist. Mögliche
Ursachen: Verschmutzung von Sensor oder Reflektor, Sensor ist dejustiert, Leitung ist
beschädigt. Im Gutzustand: HIGH (1), bei zu starker Verschmutzung oder Leitungsunter‐
brechung LOW (0). Dabei blinkt die gelbe Anzeige-LED.
Tabelle 11: Alarm / Health
Alarm ( 100 mA) Health (100 mA)
+ (L+)
Alarm
‒ (M)
+ (L+)
Alarm
‒ (M)
18 Inbetriebnahme
18.1 Ausrichtung
Sensor auf geeigneten Reflektor ausrichten. Positionierung so wählen, dass der rote
Sendelichtstrahl in der Mitte des Reflektors auftrifft. Der Sensor muss freie Sicht
auf den Reflektor haben, es darf sich kein Objekt im Strahlengang befinden [siehe
Abbildung 10]. Es ist darauf zu achten, dass die optischen Öffnungen von Sensor und
Reflektor vollständig frei sind.
17 ZUSATZFUNKTIONEN
18
8020352.19RH / 15.01.2021 | SICK
Subject to change without notice
Abbildung 10: Ausrichtung
18.2 Einsatzbedingungen prüfen
Distanz zwischen Sensor und Reflektor mit dem zugehörigen Diagramm [siehe
Tabelle 12] abgleichen (x = Schaltabstand, y = Funktionsreserve).
Tabelle 12: Einsatzbedingungen
0 4 8 12 16
100
10
1
Funktionsreserve
Abstand in m
4
3
1
7
6
5
Betriebs-
reichweite
2
WLD16P-xxxxx1xx
Abbildung 11: Kennlinie 1
1
Reflektor PL22
2
Reflektor P250
3
Reflektor PL20A
4
Reflektor PL30A
5
Reflektor PL40A
6
Reflektor C110
7
Reflektor PL80A
0
Schaltabstand
Abstand in m
0,3 4
6
0,25 8
12
0,25 8
12
0,25 4
6
0,25 8
12
0,25 10
14
0,25 10
14
1
2
3
4
5
6
7
Schaltabstand max.
4 8 12 16
Abbildung 12: Balkendiagramm 1
INBETRIEBNAHME 18
8020352.19RH / 15.01.2021 | SICK
Subject to change without notice
19
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101

SICK WLD16 Instruções de operação

Tipo
Instruções de operação