C60T379A2.qxd 14/3/07 16:10 Página 23
ES MANUAL DE UTILIZACIÓN
EN GUIDE TO INSTALLATION
FR GUIDE D'UTILISATION
DE BETRIEBSANLEITUNG
PT GUIA DE UTILIZAÇÃO
PPllaaccaa ddee ccoocccciióónn
CCooookkiinngg HHoobb
TTaabbllee ddee ccuuiissssoonn
KKoocchhffeelldd
PPllaaccaa ddee ccoozziinnhhaa
ES MANUAL DE UTILIZACIÓN
EN GUIDE TO INSTALLATION
FR GUIDE D'UTILISATION
DE BETRIEBSANLEITUNG
PT GUIA DE UTILIZAÇÃO
M
A
N
U
A
L
D
E
I
N
S
T
A
L
A
C
I
Ó
N
Y
U
S
O
D
E
L
A
P
A
R
A
T
O
C60T357A4.qxd 14/3/07 15:55 Página 1
PLACAS DE INDUCCIÓN
INSTALACIÓN
1
DESCRIPCIÓN DEL APARATO
2
DIMENSIONES DE ENCASTRE
Su aparato debe estar colocado de forma que la instalación a la red eléctrica esté accesible.
La distancia entre el borde de la placa y la pared (o tabique) lateral o trasera debe ser de al
menos 40 mm (zona A).
Pegue la junta de espuma debajo de la placa siguiendo el contorno de las superficies de
apoyo con su encimera. De este modo conseguirá una buena estanqueidad con la encimera.
Fije los enganches de la placa al mueble.
No utilizar materiales no removibles como la silicona.
4
A
A
A
B
B C B
C
D
D
Entrada de aire
580
490
64
40
40
40
A
560
510
Salida de aire
Vidrio vitrocerámico
Cable de alimentación
C60T357A4.qxd 14/3/07 15:55 Página 4
DIMENSIONES DE ENCASTRE
5
65
65
65
288
65
40 máx.
60 máx.
40 máx.
40 máx.
510
510
490
510
410
440
490
490
930
930
770
900
900
270
750
C60T357A4.qxd 14/3/07 15:55 Página 5
Coloque la placa en el hueco del
mueble presionando bien para
que la junta de estanqueidad
haga buen cierre.
Amarre los cuatro enganches de
la placa por la parte inferior en las
esquinas del hueco.
Los circuitos electrónicos de su placa de inducción deben enfriarse por una corriente
de aire fresco como se indica en el esquema.
40mm mínimo
50mm
Placa sobre Horno Placa sobre Mueble
50mm
5mm mínimo 5mm mínimo
6
IMPORTANTE
La instalación debe garantizar que llegue aire fresco por la parte trasera y que tenga una
salida en la parte delantera de al menos 5 mm.
3
FIJACIÓN EN LA ENCIMERA
4
LUGAR DE INSTALACIÓN
A
B
C60T357A4.qxd 14/3/07 15:55 Página 6
7
UTILIZACIÓN PLACAS
DE INDUCCIÓN
UTILIZACIÓN
Tamaño foco Pot. Tipo “A” Pot. Tipo “B”
(cm)
16 2.200w 2.000w
18 2.800w 2.800w
21 3.100w 3.100w
28 3.600w 2.800w
TIPO A
TIPO B
POTENCIA DE CADA FOCO
TIPO DE APARATO
1
Los aparatos tipo
"A" llevan mandos
con funciones
especiales o con
funciones basicas
Los aparatos tipo
"B" llevan mandos
compactos
C60T357A4.qxd 14/3/07 15:55 Página 7
19
220-240 V monofásica
Fusible 32 amperios
Neutro
N
Marrón
Verde/Amarillo
Azul
Negro o gris
Marrón
Verde/Amarillo
Azul
Negro o gris
Marrón
Verde/Amarillo
Azul
Negro
Gris
Fase
L
Tierra
400 V 2N trifásica
Fusible 16 amperios
2 x 230 V trifásico
Separe los 2 cables de fase L1,L2
antes de efectuar la conexión.
Separe los 2 cables de fase L1,L2
y Neutro N1 N2 antes de efectuar
la conexión.
Neutro
N
Fase1
L1
Fase2
L2
Tierra
Neutro 1
Neutro 2
N1 N2
Fase1
L1
Fase2
L2
Tierra
CONEXIÓN ELÉCTRICA
CABLES DE 3 HILOS
CABLES DE 5 HILOS
6
400 V 3N trifásica
Fusible 16 amperios
Neutro
N
Fase
L1
Tierra
Marrón
Verde/Amarillo
Azul
220-240 V monofásica
Fusible 16 amperios
16A
Verde/Amarillo
Azul
Neutro
N
Tierra
Marrón
Fase
L
C60T357A4.qxd 14/3/07 15:56 Página 19
20
400 V 3N trifásica
Fusible 16 amperios
220-240 V monofásica
Separe los 2 cables de fase L1,L2
antes de efectuar la conexión.
Neutro
N
Fase
L
Tierra
Neutro
N
Fase
L3
Fase
L1
Fase
L2
Tierra
Marrón
Verde/Amarillo
Azul
Negro o gris
Marrón
Verde/Amarillo
Azul
Marrón
Verde/Amarillo
Azul
Negro o gris
Marrón
Verde/Amarillo
Azul
IMPORTANTE
La placa se suministra con cable de alimentación. Si el cable de alimentación está dañado
debe ser sustituido por el fabricante, servicio postventa o personal autorizado con el fin de
evitar un peligro.
Al poner la placa bajo tensión o después de un corte de corriente prolongado aparecerá
un código luminoso en el panel de mandos.
220-240 V monofásica
Fusible 16 y 32 amperios
32A 16A
Neutro
N
Marrón
Verde/Amarillo
Azul
Negro o gris
Verde/Amarillo
Azul
Fase
L
Tierra
Neutro
N
Tierra
Marrón
Fase
L
CABLES DE 8 HILOS
C60T357A4.qxd 14/3/07 15:56 Página 20
ADVERTENCIAS SOBRE EL MEDIO AMBIENTE
Con objeto de preservar el medio ambiente entregue su aparato usado en un centro
oficial de recogida o recuperación de materiales reciclables.
Antes de deshacerse de su aparato usado inutilícelo, cortando el cable de conexión
con el enchufe.
22
C60T357A4.qxd 14/3/07 15:56 Página 22
23
C60T357A4.qxd 14/3/07 15:56 Página 23
03-07 C60T357A4
Impreso en papel reciclado
C60T357A4.qxd 14/3/07 15:56 Página 24
A
P
P
L
I
A
N
C
E
I
N
S
T
A
L
L
A
T
I
O
N
A
N
D
U
S
A
G
E
M
A
N
U
A
L
C60T376A8.qxd 14/3/07 16:21 Página 1
INDUCTION HOBS
INSTALLATION
1
DESCRIPTION OF THE APPLIANCE
2
FRAME DIMENSIONS
You appliance must be positioned so that the electricity network installation is accessible.
The distance between the edge of the hob plate and the side or rear wall (or panel) must be
at least 40 mm (zone A).
Glue the foam joint underneath the hob plate following the outline of the support surfaces with
your worktop. In this way you will get good sealing against the worktop. Fix the hob plate’s
hooks to the unit.
Do not use material which cannot be removed such as silicon.
4
A
A
A
B
B C B
C
D
D
Air inlet
580
490
64
40
40
40
A
560
510
Air outlet
Vitroceramic glass
Power cable
C60T376A8.qxd 14/3/07 16:21 Página 4
FRAME DIMENSIONS
5
65
65
65
288
65
40 máx.
60 máx.
40 máx.
40 máx.
510
510
490
510
410
440
490
490
930
930
770
900
900
270
750
C60T376A8.qxd 14/3/07 16:21 Página 5
Fit the hob into the space in the
unit pressing down well to close
the seal properly.
Fix the four hob plate hooks
underneath in the unit space cor-
ners.
There must be a current of fresh air to cool your induction hob’s electronics circuits as
shown in the diagram.
40mm minimum
50mm
Hob on oven Hob on unit
50mm
5mm minimum 5mm minimum
6
IMPORTANT
Installation must guarantee that fresh air can come from the rear and that a vent measu-
ring at least 5 mm allows the air to escape in the front part.
3
FASTENING TO THE WORKTOP
4
INSTALLATION POSITION
A
B
C60T376A8.qxd 14/3/07 16:21 Página 6
7
USING INDUCTION HOBS
USE
Hob size Type “A” power Type “B” power
(cm)
16 2.200w 2.000w
18 2.800w 2.800w
21 3.100w 3.100w
28 3.600w 2.800w
TYPE A
TYPE B
POWER OF EACH HOB
TYPE OF APPLIANCE
1
Type “A” appliances
have commands with
special functions or
with basic functions
Type "B" appliances have
compact commands
C60T376A8.qxd 14/3/07 16:21 Página 7
19
220-240 V single phase
32 amp fuse
Neutral
N
Brown
Green/Yellow
Blue
Black or grey
Brown
Green/Yellow
Blue
Black or grey
Brown
Green/Yellow
Blue
Black
Grey
Live
L
Earth
400 V 2N 3-phase
16 amp fuse
2 x 230 V three phase
Separates the 2 live cables L1, L2
before making the connection.
Separates the 2 live cables L1, L2
and Neutral N1 N2 before making
the connection.
Neutral
N
Live1
L1
Live2
L2
Earth
Neutral 1
Neutral 2
N1 N2
Live1
L1
Live2
L2
Earth
ELECTRICAL CONNECTION
3 WIRE CABLES
5 WIRE CABLES
6
400 V 3N three phase
16 amp fuse
Neutral
N
Live
L1
Earth
Brown
Green/Yellow
Blue
220-240 V single phase
16 amp fuse
16A
Green/Yellow
Blue
Neutral
N
Earth
Brown
Live
L
C60T376A8.qxd 14/3/07 16:21 Página 19
20
400 V 3N 3-phase
16 amp fuse
220-240 V single phase
Separates the 2 live cables L1, L2
before making the connection.
Neutral
N
Live
L
Earth
Neutral
N
Live
L3
Live
L1
Live
L2
Earth
Brown
Green/Yellow
Blue
Black or grey
Brown
Green/Yellow
Blue
Brown
Green/Yellow
Blue
Black or grey
Brown
Green/Yellow
Blue
IMPORTANT
The hob plate is provided with a power cable. If the power cable is damaged it must be
replaced by the manufacturer, after sales service or authorised personnel in order to avoid
danger.
When switching the hob plate on for the first time or after a long time without use, a code
will light up on the command panel.
220-240 V single phase
16 and 32 amp fuses
32A 16A
Neutral
N
Brown
Green/Yellow
Blue
Black or grey
Verde/Amarillo
Blue
Live
L
Earth
Neutral
N
Earth
Brown
Live
L
CABLES DE 8 HILOS
C60T376A8.qxd 14/3/07 16:21 Página 20
23
C60T376A8.qxd 14/3/07 16:21 Página 23
03-07 C60T376A8
Printed on recycled paper
C60T376A8.qxd 14/3/07 16:21 Página 24
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130

Groupe Brandt IF-900S Manual do proprietário

Categoria
Fogões
Tipo
Manual do proprietário
Este manual também é adequado para